    Wireless dual-zone PIR motion detector

    €110,70 IVA incluido
    The JA-86P is a component of Jablotron’s Oasis 80 alarm system. It is designed to detect human body movement inside buildings. Detection in two zones makes this detector more immune to moving pets. The battery-powered detector communicates via OASIS radio protocol.
    SKU: JA-86P
    Ship to
    *
    *
    Shipping Method
    Name
    Estimated Delivery
    Price
    No shipping options
    Disponibilidad: Producto descatalogado - confirmar disponibilidad antes de realizar el pedido





    TechInfo:

    • Voltage: Lithium battery type LS(T)14500 (3.6V AA);
    • Battery life: typically 3 years (sleep mode 5min.);
    • Communication band: 868 MHz, Oasis protocol;
    • Communication range: typically 300m (open area);
    • Recommended installation height: 1.2 m above the floor;
    • Detection angle / range: 120° / 12 m (with basic lens);
    • Operational environment according to EN 50131-1: II. indoor general;
    • Operational temperature range: -10 to +40 °C;
    • Dimensions: 180 x 60 x 55 mm;
    • EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification: grade 2;
    • Complies with: ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1;
    • Can be operated according to: VO-R/10/03.2007-4;









    Escriba su propia opinion
    • Solo los usuarios registrados pueden agregar sus comentarios
    *
    *
    • Malo
    • Excelente
    *
    *
    *
    *





    TechInfo:

    • Voltage: Lithium battery type LS(T)14500 (3.6V AA);
    • Battery life: typically 3 years (sleep mode 5min.);
    • Communication band: 868 MHz, Oasis protocol;
    • Communication range: typically 300m (open area);
    • Recommended installation height: 1.2 m above the floor;
    • Detection angle / range: 120° / 12 m (with basic lens);
    • Operational environment according to EN 50131-1: II. indoor general;
    • Operational temperature range: -10 to +40 °C;
    • Dimensions: 180 x 60 x 55 mm;
    • EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification: grade 2;
    • Complies with: ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1;
    • Can be operated according to: VO-R/10/03.2007-4;